Provide a vertical and horizontal channel for air flow and moisture.
Furring strips for horizontal wood siding.
To correct an uneven wall use furring strips and wood shims if necessary to eliminate low spots.
Corners are often needlessly fortified with furring strips or strapping where they should ideally be left open and able to dry.
Every piece of 1 in.
Extend the life of your siding and paint by eliminating heat and moisture build up.
Quarrix furring strips will not warp or split like others.
Proven performance over wood.
Even worse once the trapped water is inside the wall cavity it is absorbed by the wood furring strip.
Create a level surface for attaching wallboard and paneling.
Use untreated 1 4 furring.
Furring strip board is perfect for a wide range of uses including carpentry hobbies shelving and general finish work.
Ensure a maximum spacing of 16 center to center c c between furring strips figure 3.
Establish an air space perfect for masonry insulation and cedar shingle projects.
A horizontal furring strip prevents this from happening.
Install a continuous strip of cor a vent sv 5 at top and bottom of the rain screen to prevent bug entry.
3 8 inch thick x 1 1 2 inch wide polypropylene furring strips attached vertically over air moisture barrier at face of each supporting stud to create capillary break between face of air moisture barrier and back of siding equal to cor a vent sturdi strips with sv 3 siding vent continuous at top and bottom by cor a vent inc.
Our furring strips are made of a plastic material that is crush resistant and resists moisture mold mildew.
We expect that installation of wood based siding applied over furring strips ac celerates drying of rain wetted siding particularly when installed over foam sheathing.
Siding installed over wood fiberboard sheathing.
With a horizontal wood furring strip any wind driven rain that gets behind the siding is a problem they prevent gravity from draining the water out of the bottom.
Horizontal furring strips can stop air flow and prevent water from draining out.
For best results space horizontal furring strips 12 on center.
Do not exceed 16.
It is the installer s responsibility to ensure the furring strips are properly secured to the structure.
Double furring at the corners.
Builders began installing wood siding over wood furring strips usually plaster ing lath.
Furring strips for use behind sheet siding.
Nail on blocking for rabbeted trim leaving space for cor a vent sv 5.
Diagonally installed furring is an option that can also work without needing a second layer.
During the 1950s some u s.
Install horizontal furring to allow attachment of vertical siding.